The settings for Fonts, Mouse, Keyboard, etc., can be changed from Utilities > Settings >

Set the text of different global controls/graphics:

- Control- Changes the text fonts of the OpendTect window.
- Graphics large/medium/small- Changes the fonts of large/medium/small graphics within certain windows e.g. survey box.
- Small/Large Controls- Changes the fonts of small/large controls within specific windows e.g. the small controls (the text describing inline/crossline/Z-ranges or bin size) of survey selection window.
Clicking any of the function buttons will pop up a standard font-selection window.

Standard font selection window
The Look and Feel option is used to change standard settings of OpendTect icon size, color bar orientation, toggling shading & volume rendering on/off.
Set mouse button functions. System administrators can implement user-defined mouse button actions. See the Application Management Documentation for details.
Define custom keyboard shortcuts to move slice forward/backward. Set either one key (set first key to no-button) or a combine control/shift key with another key of choice from the list.
The ADVANCED user settings changes the default settings of specific keywords. Specify settings and/or setup or edit the Survey default settings.

The settings can be found in the .od/ directory from the user home directory. Depending on the platform used, this is located in:
- /home/username/.od for Linux users
- root > Documents and Settings > username>.od in Windows 2000, XP and 2003
- root > Users > username >.od in Windows Vista and 7
- Users > username > .od for Mac users
To list the type of current Personal and/or Survey settings, type l ~/.od/*DTECT_USER* in Linux console.
The following files are used to store the Personnal settings:
- settings.DTECT_USER: File is used to setup Personal settings
- settings_coltabs.DTECT_USER: File is used to edit colorbar display properties
- settings_snapshot.DTECT_USER: File allows the user to edit the snapshot properties like resolution, height, width etc ..
- settings_flatview.DTECT_USER: File enables the user to edit the 2D viewer properties like Variable Density, Wiggle Variable Area.
- settings_welldisp.DTECT_USER: File enables the user to edit the well display properties
- settings_welltie.DTECT_USER: File is used to edit the Well to Seismic tie properties like Velocity/Density names, Wavelet ID etc..
- qtsettings.DTECT_USER: File will allow the user to edit the QT properties
- settings_3DPSViewer.DTECT_USER: File will allow the user to edit the 3D PreStack viewer properties
- settings_GMT.DTECT_USER: File will allow the user to edit the GMT properties
- survey.DTECT_USER: File is used to edit the Default Survey. Typing cds from a linux console will bring the user back to his/her default survey
Update Personal Settings by specifying a keyword (a variable name) and its value. The list pops up by pressing the Select existing button in the Set Personal Settings dialog (see below). A brief description on the available variables (and the values) is given below:

Note: Most of the changes are updated after restarting the OpendTect, other are activated instantly.
Pre-defined Keywords:
Press Select existing button to bring up pre-defined keywords. After selection of any variable, the values should be updated. The values are updated by pressing 'OK' button.
- Common:
- Company: Write the company name. Keyword - Company, Value: Text (e.g. dGB Earth Sciences).
- Default DATA directory: Set up a default OpendTect data directory. The value is a path pointing to a data directory e.g. /disk/ODData/.
- Fonts: Set fonts for OpendTect controls and graphics via the Font.* or Graphic.* keywords. The wild card character (*) refers to the text followed by the Font/Graphic word. All of these key words refer to a font dialog that may have a specific value. For instance, a value is written as Times New Roman`12`Normal`No [Font, Size, Style, Others]. The following keywords can have the similar values:
Font.def.Fixed width, Font.def.Graphics large, Font.def.Graphics medium, Font.def.Large control, Font.def.Small control, Font.for.Annotations, Font.for.Title, Graphics large font size, Graphics small font size.
- Icons.size: Set size of OpendTect icons. Its value can be a numeric number e.g. 20, 24, 32 etc.
- In-line byte: Set the inline byte location
- Pre-stack Viewer Settings (3D PS Viewer.*)
:With value=1,the Prestack viewer will change in autowidth mode
- Bold font: With Value set to 'Yes', the font is set to bold
- Cross-line byte: Set up the default cross-line byte location
- Default display quantity:
- Dialog font size:
- Display Table style:
- Display UnitID: Display the help window ID
- Font face:
- Help viewer:
- Hor field offset:
- MultiMachine.Nr inline per job: Optional overruling of number of jobs (i.e. number of inlines) for each machine while running multi-machine batch processing. Default value is 3.
- Nr Processors: Numeric number to specify the number of processors used for processing. E.g. '0' means use all processors.
- dTect.Measure LineStyle: Standard settings for the distance measurement tool available in the Graphics Toolbar.
- Printer:
- Query before remove:
- SU pick file:
- Seg-Y headers: Default file location for dumping SEG-Y headers. The value is the output path together with a file name (e.g. /disk/SGY_dump.txt).
- SEG-Y.Examine.Number of traces: Set a minimum numeric value (e.g. 100) for examining SEG-Y files.
- Ui.ToolTips.enable: Enables the tool tip guide. Set either Yes/No.
- dTect.Ask.*: Set to prompt a warning message settings (Value: Yes/No) for several windows. Prompt included when exiting OpendTect, closing Attribute Set window, storing picksets, storing sessions etc.
- dTect.Auto Attribute set: Set default attribute set-name that will be auto loaded when OpendTect is launched.
- dTect.Average even median:
- dTect.Color table.Name: Set the default color table. By default the Red-White-Blue color scheme. Set value as a color table name.
- dTect.ColorBar.show on top: Use value Yes/No to set the color table on top in the scene.
- dTect.ColorBar.show vertical: Set value to Yes/No for default orientation of the color table (vertical = Yes).
- 2D Viewer Settings (SeisView.*):.2D Viewer Display Properties of Wiggle Variable Area
The following keywords can have the similar values:
SeisView.Display.WVA.Clipping, SeisView.Display.WVA.Display Null traces, SeisView.Display.WVA.Draw wiggles, SeisView.Display.WVA.Interpolate, SeisView.Display.WVA.Left color, SeisView.Display.WVA.Min Pix/Trace, SeisView.Display.WVA.Overlap, SeisView.Display.WVA.Reftime color, SeisView.Display.WVA.Reverse order, SeisView.Display.WVA.Reverse polarity, SeisView.Display.WVA.Right color, SeisView.Display.WVA.Show reftime, SeisView.Display.WVA.Var Area.
- Show modifiers:
- Vert field offset:
- dTect.DTECT_SHOW_HELP: Show ID on the help-window icon
- dTect.Disp.Default auto symmetry:
- dTect.Disp.Default histogram equalisation:
- dTect.Disp.Default clip perc: Set a default clipping value (1-100 %) for clipping the seismic data.
- dTect.Default symmetry zero:This will set the color bar symmetry around zero
- dTect.Dont load plugins: Set to either load or not load plugins (subject to availability)
- dTect.Dump OI Menu: Special setting to export a OpendTect scene. Set value Yes/No to make option available.
- dTect.Enable VRML:
- dTect.Icons.size: Set a default numeric value for OpendTect icons size.
- dTect.ProcessVolumeBuilderOnOK: Volume Builder setup. By default the value is Yes i.e the set up processes the volume based on the available volume builder setup.
- dTect.Show inl progress: Set Yes/No to show or hide the inline progress bar while displaying the data.
- dTect.Use VolRen shading: Set Yes/No for volume rendering shading.
- dTect.Use shading: Set Yes/No for shading.
- dTect.Zoom factor: Set a value for wheel zooming factor. Default value is 1.
- dTect.KeyBindings.Default:
- dTect.Mousecontrols.Default:
- dTect.MouseInteraction.DepthKey:
- dTect.MouseInteraction.PlaneKey:
- dTect.Select Plugins: Select/de-select plugins
- dTect.VolRen shading: Set Yes/No for shading
- dTect.Use startup session: Directly start a session when opening a specific survey in OpendTect
This option enables the user to setup/edit the Survey default settings

Depending on the user, several settings are available. Let us describe few:
- 3DAttrset.Auto ID: This setting shows the ID value of the default auto-load attribute set.
- Default.Cube: This will show you the default cube ID. If there is no value, this will mean that no Default Cube was set in that survey. To set a Cube as default, go to "Manage Seismic Data" in the main OD interface then click on the 'set as default'
icon after a cube has been selected.
- Default.LineSet: This will show the ID value of the default 2D LineSet.
- Depth in feet: Change the Value to 'No' if the Depth is in meter.
- SEG-Y Rev.1 policy: When importing the SEG-Y,If the value is set to 1 the window will pop up asking a user to confirm the Rev1. With the value = -1 no confirmation pop-up window.
- Show depth in feet: This option enables the user to show the depth in meter if the value is set to 'No'. Setting the value to "Yes' will display the depth in feet
- Z Scale: This shows the value of the survey Z-scale
- Z Stretch: This setting shows the ID value of the stretch